Wall ties should be metal ties to BS 1243 or other approved ties and should be bedded to a minumum depth of 50mm. Additional ties should be provided within 225mm of all openings such that there is at least one for each 300mm of height and opening. Consideration should be given providing additional flexible ties across the cavity adjacent to movement joints. Butterfly wall ties are generally reccommended for party walls to maximise sounds insulation.